Gilbert · Maricopa County, AZ
Commercial fire protection in Gilbert, AZ
Fire Solutions NW inspects, tests, repairs and monitors fire sprinklers, fire alarms, extinguishers, kitchen hood suppression and backflow assemblies for commercial buildings in Gilbert and across Maricopa County. Licensed in Arizona. Call 1-855-876-3473.
Get a Free QuoteFire protection services in Gilbert
- Fire sprinkler inspection, testing & repair (NFPA 25)
- Fire alarm inspection, testing & installation (NFPA 72)
- 24/7 fire alarm monitoring
- Fire extinguisher service (NFPA 10)
- Kitchen hood suppression (NFPA 17A / 96)
- Backflow testing
- Fire pump testing
- Emergency & exit lighting
- Help after a failed fire inspection
Fire code and inspections in Gilbert
Commercial fire inspections and fire protection system permits in Gilbert are handled by the Gilbert Fire and Rescue Department, Fire Prevention Division. We schedule inspections, testing and repairs to keep your building current with what they look for.
The Town of Gilbert's code adoption page lists the 2018 IFC (Ordinance 2739, adopted January 1, 2020). A newer adoption was not verified. (source)
Local requirement: Gilbert Fire Prevention Division Regulation 12-901.6.1 (effective February 25, 2016) requires copies of system ITM records to go to the fire code official. It names no portal. (source)
Your fire marshal (the authority having jurisdiction) has the final say, so we confirm local requirements before work is scheduled.
Areas we serve near Gilbert
We also serve Mesa, Chandler, Queen Creek, Higley, Tempe and the surrounding area.
Other cities we serve in Maricopa County: Phoenix, Scottsdale, Glendale.
Arizona licensing
Fire Solutions NW LLC is licensed in Arizona:
- Arizona ROC C-16 Fire Protection Systems: ROC 344811 (verify)
- Arizona ROC C-67 Low Voltage Communication Systems: ROC 343913 (verify)
See all state licenses on our licenses page.
Common questions
How often do fire sprinklers need to be inspected in Gilbert?
Sprinkler systems follow NFPA 25, which sets weekly, monthly, quarterly and annual inspection and testing tasks plus a five-year internal pipe assessment. The Gilbert Fire and Rescue Department, Fire Prevention Division enforces these requirements in Gilbert. We set up a recurring schedule so nothing is missed.
How often do fire extinguishers need service in Gilbert?
Under NFPA 10, extinguishers get a monthly visual check, annual maintenance by a qualified technician, and periodic internal maintenance and hydrostatic testing based on the extinguisher type.
How often does a kitchen hood suppression system need inspection?
Restaurant hood suppression systems are inspected every six months under NFPA 17A and NFPA 96.