King County · Commercial fire protection
Fire protection,done right in Federal Way.
Commercial fire protection, inspection, and testing for Federal Way facilities — retail centers along the I-5 and SR-99 corridors, medical office, multifamily, and light-industrial sites between Seattle and Tacoma.
Why Federal Way is different
The Federal Way commercial fire-protection landscape.
Federal Way sits on the King–Pierce county line and is built around two commercial spines: Pacific Highway South (SR-99) and the I-5 corridor. Property types skew toward regional retail and shopping centers, hotels, medical and dental office, a large multifamily stock, and office campuses being redeveloped for new uses. Fire prevention for the city is handled by South King Fire (King County Fire Protection District 39), which also covers Des Moines — so a single portfolio can span two cities under one fire marshal.
AHJ
South King Fire — Fire Marshal’s Office
South King Fire (King County Fire Protection District 39) provides fire prevention for Federal Way and Des Moines. Construction permits run through the City of Federal Way Community Development department.
Visit AHJ site ↗County
King County
Multi-site portfolios across the county coordinated on one service calendar with routing to the correct AHJ per property.
Codes enforced
- 2021 IFC (with WA amendments)
- NFPA 72 (fire alarm)
- NFPA 25 (sprinklers)
- NFPA 10 (extinguishers)
- NFPA 96 (kitchen hoods)
What we protect in Federal Way
Properties we serve.
Retail centers & SR-99 commercial
Anchor-and-pad shopping centers, big-box retail, and strip centers along Pacific Highway South and near The Commons. Multi-tenant sprinkler risers, tenant-improvement alarm changes, and extinguisher service across many suites on one schedule.
Medical & dental office
Clinics, ambulatory care, and medical office buildings that need annual NFPA 72 alarm testing, emergency lighting, and clean documentation for landlords and insurers.
Multifamily & hotels
Apartment communities and hotels near I-5 with annual sprinkler and alarm ITM, common-area extinguishers, and kitchen hood service in restaurants and amenity spaces.
Services available in Federal Way
Every system,one accountable partner.
Fire Alarm Systems
We design, install, inspect, and test addressable and conventional fire alarm systems so your building stays code-compliant and your occupants stay protected — with clean, AHJ-ready documentation after every visit.
Learn more
Fire Sprinkler Systems
NFPA 13 and NFPA 25 compliant inspection, testing, maintenance, and installation of fire sprinkler systems for commercial and industrial facilities across the Pacific Northwest and Southwest.
Learn more
Fire Extinguishers
NFPA 10 portable fire extinguisher inspection, annual maintenance, 6-year internal maintenance, and 12-year hydrostatic testing. Keep every extinguisher on your property code-ready.
Learn more
Kitchen Hood Suppression
Semi-annual inspection and testing of UL 300 wet-chemical kitchen hood suppression systems for restaurants, commercial kitchens, and food service facilities.
Learn more
Emergency & Exit Lighting
Monthly 30-second tests and annual 90-minute load testing of emergency and exit lighting per NFPA 101 Life Safety Code. Keep egress paths code-compliant.
Learn more
24/7 Alarm Monitoring
UL-listed central-station monitoring with rapid dispatch, full event logging, and multi-path signaling. Fire, burglar, and environmental monitoring for commercial and residential properties.
Learn more
FAQ
Common Federal Way questions.
Who is the fire marshal for commercial buildings in Federal Way?+
South King Fire, also known as King County Fire Protection District 39, provides fire prevention and code enforcement for Federal Way and Des Moines. Building and construction permits are handled by the City of Federal Way. We route inspection reports to the correct office for your address.
How often do Federal Way businesses need fire alarm and sprinkler inspections?+
Under the Washington State Fire Code (IFC with state amendments) and the NFPA standards it references, fire alarm systems need annual inspection and testing (NFPA 72) and sprinkler systems need inspection on weekly, monthly, quarterly, annual, and five-year intervals (NFPA 25). Extinguishers need annual maintenance and periodic hydrostatic testing (NFPA 10).
Can you service a portfolio across Federal Way, Kent, Tacoma, and the South Sound?+
Yes. We schedule multi-site portfolios on one service calendar, consolidate reporting, and bill by site or by portfolio — including properties split between King and Pierce counties.
Do you handle kitchen hood suppression for Federal Way restaurants?+
Yes. Kitchen hood suppression systems need semi-annual inspection and service under NFPA 96 and the system manufacturer’s requirements. We service hood systems and coordinate with your hood-cleaning vendor.
Information general to Federal Way commercial fire protection; your AHJ has final authority on specific requirements for your property.
Request a Federal Way quote
Start a conversation about yourFederal Way facility.
Tell us about your property. A Federal Way-area specialist replies within one business day.
1-855-876-3473Mon–Fri 7:00 AM – 4:00 PM PT · 24/7 emergency dispatch

